山东大学学报(医学版) ›› 2017, Vol. 55 ›› Issue (3): 54-58.doi: 10.6040/j.issn.1671-7554.0.2016.811
常飞1,姜宝岐2,董作青1,刘佳3,徐欣2
CHANG Fei1, JIANG Baoqi2, DONG Zuoqing1, LIU Jia3, XU Xin2
摘要: 目的 从实验角度观察初期稳定性对HA涂层、软组织水平、根形种植体即刻种植成功率的影响,以期为临床手术中的操作提供理论依据。 方法 将成年杂种犬双侧下颌后牙区种植位点随机分为两组:实验组(植入ISQ值<50)和对照组(植入ISQ值>65),通过测量植入当时及第4、8、12周种植体ISQ值、同期拍摄CT、光学显微镜下计算种植体-骨结合率,观察植入种植体时不同ISQ值对即刻种植成功率的影响。 结果 种植体植入时ISQ值在28~49区间,对应植入力矩值在10~20 N以内,与对照组相比,即刻种植BLB种植体的成功率无统计学差异。植入后3个月,所有种植体均无松动、脱落,CT示种植体周围骨密度无统计学差异,种植体-骨结合率与对照组相比无统计学意义(P>0.05)。 结论 即刻种植BLB植体初期的ISQ值在28~49区间及68~75区间,对应植入力矩值在10~20 N以内及30 N以上,其成功率无统计学差异。
中图分类号:
[1] Jeong MA, Kim SG, Kim YK, et al. A multicenter prospective study in type IV bone of a single type of implant[J]. Implant Dent, 2012, 21(4): 330-334. [2] Degidi M, Daprile G, Piatteli A. Implants inserted with low insertion torque values for intraoral welded full-arch prosthesis:1-year follow-up[J]. Clin Implant Dent Relat Res, 2012, 14(suppl 1): e39-45. [3] 戴巧群, 林映荷. 即刻负荷种植体初期稳定性的测量和影响因素[J]. 广东牙病防治, 2007, 15(12): 564-565. DAI Qiaoqun, LIN Yinghe. The measurement and influencing factors of the initial stability of the immediate loading implant[J]. Guangdong dental disease prevention and control, 2007, 15(12): 564-565. [4] Manzano-Moreno FJ, Herrera-Briones FJ, Bassam T, et al. Factors affecting dental implant stability measured using the ostell mentor device: a systematic review[J]. Implant Dent, 2015, 24(5): 565-577. [5] Trisi P, Berardini M, Falco A, et al. Effect of implant thread geometry on secondary stability, bone density, and bone-to-implant contact: a biomechanical and histological analysis[J]. Implant Dent, 2015, 24(4): 384-391. [6] Gomez-Roman G, Schulte W, d Hoedt B, et al. The frialit-2 implant system: five-year clinical experience in single-tooth and immediately postextraction applications[J]. Int J Oral Maxillofac Implants, 1997, 12(3): 299-309. [7] Strub JR, Jurdzik BA, Tuna T. Prognosis of immediately loaded implants and their restorations: a systematic literature review[J]. J Oral Rehabil, 2012, 39(9): 704-717. [8] Sençimen M, Gülses A, Ozen J, et al. Early detection of alterations in the resonance frequency assessment of oral implant stability on various bone types: a clinical study[J]. J Oral Implantol, 2011, 37(4): 411-419. [9] Esposito M, Grusovin MG, Maghaireh H, et al. Interventions for replacing missing teeth: different times for loading dental implants[J]. Cochrane Database Syst Rev, 2013, 28(3): CD003878. doi: 10.1002/14651858.CD003878 [10] Shin SY, Shin SI, Kye SB, et al. The Effects of defect type and depth, and measurement direction on the implant stability quotient value[J]. J Oral Implantol, 2015, 41(6): 652-656. [11] Yurttutan ME, Kestane R, Keskin A, et al. Biomechanical evaluation of oversized drilling on implant stability- an experimental study in sheep[J]. J Pak Med Assoc, 2016, 66(2): 147-150. [12] Glauser R, Sennerby L, Meredith N, et al. Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants[J]. Clin Oral Implants Res, 2004, 15(4): 428-434. [13] Soares PB, Moura CC, Claudino M, et al. Influence of implant surfaces on osseointegration: a histomorphometric and implant stability study in rabbits[J]. Braz Dent J, 2015, 26(5): 451-457. [14] Al-Nawas B, Groetz KA, Goetz H, et al. Comparative histomorphometry and resonance frequency analysis of implants with moderately rough surfaces in a loaded animal model[J]. Clin Oral Implants Res, 2008, 19(1): 1-8. [15] Rasmusson L, Kahnberg KE, Tan A. Effects of implant design and surface on bone regeneration and implant stability: an experimental study in the dog mandible[J]. Clin Impel Dent Relat Res, 2001, 3(1): 2-8. [16] Rabel A, Kohler SG, Schmidt-Westhausen AM. Clinical study on the primary stability of two dental implant systems with resonance frequency analysis[J]. Clin Oral Investig, 2007, 11(3): 257-265. [17] Akça K, Chang TL, Tekdemir I, et al. Biomechanical aspects of initial intraosseous stability and implant design: a quantitative micro-morphometric analysis[J]. Clin Oral Implants Res, 2006, 17(4): 465-472. [18] Gehrke SA, Guirado JL, Bettach R, et al. Evaluation of the insertion torque, implant stability quotient and drilled hole quality for different drill design: an in vitro Investigation[J]. Clin Oral Implants Res, 2016 Mar 8. doi: 10.1111/clr.12808. [19] Degidi M, Daprile G, Piattelli A. Primary stability determination by means of insertion torque and RFA in a sample of 4,135 implant[J]. Clin Implant Dent Relat Res, 2012, 14(4): 501-507. |
[1] | 温艳丛, 王文娟. 拔牙位点保存技术的应用[J]. 山东大学学报(医学版), 2014, 52(S2): 80-81. |
|