JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES) ›› 2017, Vol. 55 ›› Issue (7): 103-109.doi: 10.6040/j.issn.1671-7554.0.2017.237

Previous Articles     Next Articles

TiRobot-assisted percutaneous screw fixation in unstable pelvic ring fractures

LIU Huashui1, DUAN Shengjun1, JIA Fengshuang1, LIU Shidong1, CHEN Hua2, WANG Yeben1, JIA Tanghong1, ZHAO Guohui1, ZHU Liming1, LIU Mincen1   

  1. 1. Department of Traumatology, Third Peoples Hospital of Jinan, Jinan 250113, Shandong, China;
    2. Department of Traumatology, General Hospital of Chinese PLA, Beijing 100852, China
  • Received:2017-03-21 Online:2017-07-10 Published:2017-07-10

Abstract: Objective To explore the clinical efficacy of TiRobot-assisted percutaneous screw fixation in the treatment of unstable pelvic ring fractures. Methods The clinical data of 16 patients with unstable pelvic ring fractures treated with TiRobot-assisted percutaneous screw fixation of posterior and anterior pelvic ring during Nov. 2016 and Feb. 2017 were retrospectively reviewed, including the screw placement, operation time, X-ray number, incision length, blood loss, healing time, and postoperative functions. Results The average operation time was 65 minutes, average X-ray number was 14, average length of incision was 2 cm, and average blood loss was 35 ml. All screws were inserted in the accurate site, and no screw penetrated through bone cortex. All wounds were primary healing. No iatrogenic injury on blood vessels, nerves and organs occurred. During the followed-up of 3-6 months(average 4.2), no delayed union or malunion was observed. The Majeed score in the last follow-up visit averaged 86.7 points. Conclusion TiRobot-assisted percutaneous screw placement is minimally invasive in the treatment of unstable pelvic ring fractures, with advantages of precise and safe operation, short operation time, small trauma, and small radioactive damage.

Key words: Fracture, Robot, Fixation, Pelvis

CLC Number: 

  • R683.3
[1] Ward EF, Tomasin J,Vander Griend RA. Open reduction and internal fixation of vertical shear pelvic fractures[J]. J Trauma, 1987, 27(3): 291-295.
[2] Xu P, Wang H, Liu ZY, et al. An evaluation of three-dimensional image-guided technologies in percutaneous pelvic and acetabular lag screw placement[J]. J Surg Res, 2013, 185(1): 338-346.
[3] Giráldez-Sánchez MA, Lázaro-Gonzálvez Á, Martínez-Reina J, et al. Percutaneous iliosacral fixation in external rotational pelvic fractures. A biomechanical analysis[J]. Injury, 2015, 46(2): 327-332.
[4] Zhang L, Peng Y, Du C, et al. Biomechanical study of four kinds of percutaneous screw fixation in in two types of unilateral sacroiliac joint dislocation: a finite element analysis[J]. Injury, 2014, 45(12): 2055-2059.
[5] Carmack DB, Moed BR, McCarroll K, et al. Accuracy of detecting screw penetration of the acetabulum with intraoperative fluoroscopy andcomputed tomography[J]. J Bone Joint Surg Am, 2001, 83(9): 1370-1375.
[6] Gautier E, Bächler R, Heini PF, et al. Accuracy of computer-guided screw fixation of the sacroiliac joint[J]. Clin Orthop Relat Res, 2001, 393(393): 310-317.
[7] Karthik K, Colegate-Stone T, Dasgupta P, et al. Robotic surgery in trauma and orthopaedics: a systematic review[J]. Bone Joint J, 2015, 97(3): 292-299.
[8] 刘建全, 刘黎军, 黄俊锋, 等. 机器人导航定位系统辅助下经皮空心螺钉内固定治疗股骨颈骨折[J]. 中华创伤骨科杂志, 2015, 17(8): 692-698. LIU Jianquan, LIU Lijun, HUANG Junfeng, et al. Fixation with percutaneous cannulated screws assisted by robot navigation for femoral neck fractures[J]. Chinese Journal of Orthopaedic Trauma, 2015, 17(8): 692-698.
[9] 苏永刚, 王军强, 刘文勇, 等. 双平面骨科机器人系统辅助骶髂关节螺钉置人的实验研究[J]. 中华创伤骨科杂志, 2006, 8(1): 45-49. SU Yonggang, WANG Junqiang, LIU Wenyong, et al. The bi-planar navigation robot system: application for insertion of sacroiliac screws[J]. Chinese Journal of Orthopaedic Trauma, 2006, 8(1): 45-49.
[10] 苏永刚, 张维军, 王豫. 骶髂关节螺钉手术导航机器人系统设计及实验研究[J]. 北京生物医学工程, 2013, 32(4): 331-335. SU Yonggang, ZHANG Weijun, WANG Yu. Design and experimental research of a surgical navigation robotic system for sacro-iliac joint screw surgery[J]. Beijing Biomedical Engineering, 2013, 32(4): 331-335.
[11] Vaidya R, Colen R, Vigdorchik J, et al. Treatment of unstable pelvic ring injuries with an internal anterior fixator and posterior fixation: initial clinical series[J]. J Orthop Trauma, 2012, 26(1): 1-8.
[12] 祖罡, 毕大卫, 曹奇勇, 等. 髂前下棘椎弓根钉棒内固定技术在骨盆骨折中的应用[J]. 中国骨伤, 2016, 29(4): 369-372. ZU Gang, BI Dawei, CAO Qiyong, et al. Application of supra-acetabular spinal pedicle screws and a subcutaneous connecting rod(INFIX)of anterior inferior iliac spine in the treatment of pelvic fractures[J]. China Journal of Orthopaedics and Traumatology, 2016, 29(4): 369-372.
[13] 曹奇勇, 赵春鹏, 李宇能, 等. 内置外架(INFIX)治疗骨盆前环损伤[J]. 中国医刊, 2016, 51(10): 48-51. CAO Qiyong, ZHAO Chunpeng, LI Yuneng, et al. Internal fixator(INFIX)for treatment of the anterior pelvic ring injuries[J]. Chinese Journal of Medicine, 2016, 51(10): 48-51.
[14] 张彦龙, 吴春生, 宋连新, 等. 骨盆前方皮下内固定架治疗不稳定骨盆骨折[J]. 中华创伤杂志, 2015, 31(9): 828-832. ZHANG Yanlong, WU Chunsheng, SONG Lianxin, et al. Anterior subcutaneous internal fixation of unstable pelvic ring fracture[J]. Chinese Journal of Trauma, 2015, 31(9): 828-832.
[1] Wei ZHANG,Wenhao TAN,Yibin LI. Locmotion control of quadruped robot based on deep reinforcement learning: review and prospect [J]. Journal of Shandong University (Health Sciences), 2020, 1(8): 61-66.
[2] LIU Huashui, DUAN Shengjun, LIU Shidong, JIA Tanghong, JIA Fengshuang. Stoppa approach in the treatment of anterior pelvic ring fractures complicated with posterior urethral disruption [J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2016, 54(8): 88-91.
[3] ZHANG Zhenwei, FAN Xiaoyan, ZHANG Yunhua, JIANG Zhongmin. Analgesic effect of continuous thoracic paravertebral block in patients with multiple fractured ribs [J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2016, 54(6): 39-42.
[4] LIU Tao, BAO Feilong, GAO Wei, KANG Shijie, LÜ Fuxin, HU Yiming. A standard surgical protocol and outcome of treating varus posteromedial rotational instability of elbow [J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2016, 54(12): 41-45.
[5] SUN Xiangyao, HAI Yong, ZHANG Xinuo. Comparison of the adverse events of percutaneous pedicle screw fixation and traditional open pedicle screw fixation for thoracolumbar fractures: a Meta-analysis [J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2016, 54(11): 56-63.
[6] LIN Jinxiu, SUN Dongsheng, ZHENG Xiao, YIN Dechao, LI Ye, WANG Kunpeng. Impact of topical use of tranexamic acid on hidden blood loss after femoral intertrochanteric fracture fixation with PFNA [J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2016, 54(1): 67-70.
[7] DONG Wuping. Clinical outcome of unilateral external fixator combined with closed negative pressure drainage technology in the treatment of tibiofibula Gustilo Ⅲ type fracture [J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2015, 53(9): 86-89.
[8] LIU Shenghou, WANG Shaojin, LIU Wenguang, YIN Qingfeng, ZHAO Heng, XIAO Shipeng. Curative effect of domestic Wagner SL prosthesis replacement for Evans Ⅲ intertrochanteric fracture in elderly patients [J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2015, 53(8): 49-52.
[9] LI Shangzhi, LIU Haichun, WU Wenliang, CAO Cong, CHEN Yunzhen. Curative effect of mechanical stress in the treatment of nonunion [J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2015, 53(2): 22-26.
[10] QIN Xiangde, YANG Chunyun, ZHANG Yuan, NI Yihong, YU Chao, FENG Xiaoli, XU Chengwei. Changes of thrombosis molecular markers and their clinical values in type 2 diabetic patients with low extremity fractures [J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2015, 53(11): 55-58.
[11] CHU Hai-kun, SHEN Jian-hui, XU Ya-jun, DIAO Zhen-bin, WANG Nuan-feng, LI Mei4, FANG Jin-nv. Application of reconstructive fixation with plastic splint in treatment of supracondylar fracture of humerus in children [J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2014, 52(S1): 28-29.
[12] PAN Lijing, DAI Yanyan. Discussion on a method for preparation of thyroid frozen sections#br# [J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2014, 52(5): 100-103.
[13] FAN Qingkai, GONG Weiming, NING Bin, SONG Hongliang, WEI Jianlu, JIA Tanghong. Therapeutic effect of percutaneous kyphoplasty on osteoporotic multi-compressive fracture [J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2014, 52(11): 73-76.
[14] WANG Chao, ZHANG Wei, GUAN Da-wei, LI Wei, WANG Xian-quan, WANG Wen-hao. Treatment of Vancouver type B3 periprosthetic femoral fracture with greater trochanter reattachment device and cortical strut bone allograft [J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2013, 51(2): 88-92.
[15] ZHAN Zhen-jiang1, LI Ming1, ZHANG Yuan-kai1, BAI En-zhong2. Curative effect analysis of DHS and PFNA in treating intertrochanteric femoral fracture [J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2013, 51(12): 92-94.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!