JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES) ›› 2017, Vol. 55 ›› Issue (8): 82-87.doi: 10.6040/j.issn.1671-7554.0.2016.1245

Previous Articles     Next Articles

Digital anatomic basis of parallel double screws in the posterior column of the acetabulum

YU Ye1, YANG Xianwei2, XU Bo1, YAN Qi1, MU Weidong1   

  1. 1. Department of Orthopaedics, Shandong Provincial Hospital Affiliated to Shandong University, Jinan 250000, Shandong, China;
    2. Department of Orthopaedics, Peoples Hospital of Wenshang County, Jining 272500, Shandong, China
  • Received:2016-10-08 Online:2017-08-10 Published:2017-08-10

Abstract: Objective To provide a safe zone for double screws in the posterior column and to obtain the relevant parameters of two screws. Methods CT scan data of 48 pelvic specimens were analyzed. With the help of Mimics 15.0, 2 parallel cylinders(to substitute for screws)were implanted to the posterior column of the right side acetabulum, and the relevant parameters were measured. Results Posterior cylinder: The average length(L1)was(130.88±6.11)mm in males and(121.47±5.23)mm in females; the average distance(D1)to the linea terminalis was(19.65±2.45)mm in males and(17.89±2.00)mm in females; the average distance(S1)to the junction between the anterior border of iliosacral articulation and linea terminalis of pelvis was(23.71±2.61)mm in males and(25.77±3.11)mm in females. Anterior cylinder: The average length(L2)was(125.25±5.49)mm in males and(116.37±4.83)mm in females; the average distance(D2)to the linea terminalis was(13.21±1.89)mm in males and(11.62±1.39)mm in females; the average distance(S2)to the junction between anterior border of iliosacral articulation and linea terminalis of pelvis was(24.36±3.95)mm in males and(28.15±4.70)mm in females. The average angle 山 东 大 学 学 报 (医 学 版)55卷8期 -余也,等.髋臼后柱平行双螺钉数字化解剖学分析 \=-between the cylinders and horizontal plane(α), sagittal plane(β), coronal plane(γ)was(66.18±4.40)°,(10.40±2.48)°,(20.89±5.05)° in males, and(69.01±5.25)°,(5.60±2.56)°,(19.91±5.58)° in females, respectively. The maximum radius of the cylinders was 6.00 mm. Conclusion There is sufficient space for 2 parallel cylinders with the same diameter in the posterior column of the acetabulum, with the maximum radius of the cylinders being less than 6.0 mm.

Key words: Posterior column, Double lag screws, Mimics software, Anatomy

CLC Number: 

  • R641
[1] Black EA, Lawson CM, Smith S, et al. Open pelvic fractures: the University of Tennessee Medical Center at Knoxville experience over ten years[J]. Iowa Orthop J, 2011, 31: 193-198.
[2] Carroll EA, Huber FG, Goldman AT, et al. Treatment of acetabular fractures in an older population[J]. J Orthop Trauma, 2010, 24(10): 637-644.
[3] Ferguson TA, Patel R, Bhandari M, et al. Fractures of the acetabulum in patients aged 60 years and older: an epidemiological and radiological study[J]. J Bone Joint Surg Br, 2010, 92(2): 250-257.
[4] Mears DC. Surgical treatment of acetabular fractures in elderly patients with osteoporotic bone[J]. J Am Acad Orthop Surg, 1999, 7(2): 128-141.
[5] Judet R, Judet J, Lanzetta A, et al. Factures of the acetabulum: classification and guiding rules for open reduction[J]. Arch Orthop, 1968, 81(3): 119-158.
[6] Letournel E, Peltier LF, Johnson EE. Fractures of the acetabulum: a study of a series of 75 cases[J]. Clin Orthop Relat Res, 1994(305): 5-9.
[7] Kellam JF, McMurtry RY, Paley D, et al. The unstable pelvic fracture: Operative treatment[J]. Orthop Clin North Am, 1987, 18(1): 25-41.
[8] Routt Jr ML, Simonian PT, Swiontkowski MF. Stabilization of pelvic ring disruptions[J]. Orthop Clin North Am, 1997, 28(3): 369-388.
[9] Vallier HA, Cureton BA, Ekstein C, et al. Early definitive stabilization of unstable pelvis and acetabulum fractures reduces morbidity[J]. J Trauma, 2010, 69(3): 677-684.
[10] Mu WD, Wang XQ, Jia TH, et al. Quantitative anatomic basis of antegrade lag screw placement in posterior column of acetabulum[J]. Arch Orthop Trauma Surg, 2009, 129(11): 1531-1537.
[11] Goulet JA, Bray TJ. Complex acetabular fractures[J]. Clin Orthop Relat Res, 1989(240): 9-20.
[12] Schopfer A, DiAngelo D, Hearn T,et al. Biomechanical comparison of methods of fixation of isolated osteotomies of the posterior acetabular column[J]. Int Orthop, 1994, 18(2): 96-101.
[13] Ebraheim NA, XU R, Biyani A, et al. Anatomic basis of lag screw placement in the anterior column of the acetabulum[J]. Clin Orthop Relat Res, 1997, 339: 200-205.
[14] Gay SB, Sistrom C, Wang GJ, et al. Percutaneous screw fixation of acetabular fractures with CT guidance: preliminary results of a new technique[J]. AJR Am J Roentgenol, 1992, 158(4): 819-822.
[15] Chang JK, Gill SS, Zura RD, et al. Comparative strength of three methods of fixation of transverse acetabular fractures[J]. Clin Orthop Relat Res, 2001(392): 433-441.
[16] Mouhsine E, Garofalo R, Borens O, et al. Percutaneous retrograde screwing for stabilisation of acetabular fractures[J]. Injury, 2005, 36(11): 1330-1336.
[17] Tseng S, Tornetta P. 3rd. Percutaneous management of Morel-Lavallee lesions[J]. J Bone Joint Surg Am, 2006, 88(1): 92-96.
[18] Starr AJ, Reinert CM, Jones AL. Percutaneous fixation of the columns of the acetabulum: a new technique[J]. J Orthop Trauma, 1998, 12(1): 51-58.
[19] Goldstein A, Phillips T, Sclafani SJ, et al. Early open reduction and internal fixation of the disrupted pelvic ring[J]. J Trauma, 1986, 26(4): 325-333.
[20] Xu P, Wang H, Liu ZY, et al. An evaluation of three-dimensional image-guided technologies in percutaneous pelvic and acetabular lag screw placement[J]. J Surg Res, 2013, 185(1): 338-346.
[21] Ochs BG, Stuby FM, Ateschrang A, et al. Retrograde lag screw placement in anterior acetabular column with regard to the anterior pelvic plane and midsagittal plane-virtual mapping of 260 three-dimensional hemipelvises for quantitative anatomic analysis[J]. Injury, 2014, 45(10): 1590-1598.
[22] Krishnan V, Varghese V, Kumar GS. Comparative analysis of effect of density, insertion Angle and reinsertion on pull-out strength of single and two pedicle screw constructs using synthetic bone model[J]. Asian Spine J, 2016, 10(3): 414-421.
[23] 王先泉, 张伟, 孙水, 等. 髋臼前柱拉力螺钉技术内固定的临床解剖学研究[J]. 中国临床解剖学杂志, 2007, 25(2): 143-147. WANG Xianquan, ZHANG Wei, SUN Shui, et al. Clinical anatomic study of internal fixation of acetabular anterior column lag screw technique[J]. Chinese Journal of Clinical anatomy, 2007, 25(2): 143-147.
[1] LIN Ling-bo1, XIONG Chun-mei1, HAN Mei1, KONG Xiang-rong1, WANG Dao-cai2, LI Jian-zhi1, SHAO Jiang1, LIN Xiang-tao2, XIAO Lian-xiang2. Sectional anatomy of pancreas on the coronal plane
and its correlation with MSCT  images
[J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2012, 50(9): 86-.
[2] LIANG Xiao-qin1, GUO Yong-qiang2, WANG Jian-li2, HUO Ran1 . Anatomical features and free transplantation of the
posterolateral thigh perforator flap
[J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2012, 50(11): 103-.
[3] WANG Li-juan1,2, WANG Guang-bin2, LIU Yu-bo3, GENG Ming-bin4, HU Jian-bin1, BAI Xue1, ZHAO Lian-xin1. A special MR sign of brainstem infarction [J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2011, 49(5): 111-.
[4] LI Xiao1, WANG Qi-rong1, LIU Shu-wei2, HAN Fei1, GU Lin-tao1, LIANG Hui1, CUI Zhao-yang1. Lamellar sectional anatomy of the eustachian tube and its surgical significance [J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2010, 48(10): 101-104.
[5] . Clinical anatomy and surgical treatment of Ebstein′s anomaly [J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2009, 47(12): 99-101.
[6] SUN Jin-long,ZHANG Qing-lin,LI Wei-guong,WEN Chuan-yao,CUI Qing-ke,SONG Qian. [J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2006, 44(11): 1100-1103.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   