您的位置:山东大学 -> 科技期刊社 -> 《山东大学学报(医学版)》

山东大学学报(医学版) ›› 2009, Vol. 47 ›› Issue (7): 103-106.

• 论文 • 上一篇    下一篇

ReSTOR多焦点人工晶体的临床应用研究

卓建,蔡可丽   

  1. 山东大学齐鲁医院眼科, 济南 250012
  • 收稿日期:2009-01-20 发布日期:2009-07-16
  • 通讯作者: 蔡可丽,教授,研究方向白内障治疗。Email:ckl@jn.gov.cn
  • 作者简介:卓建(1979- ),男,医师,在读硕士,研究方向白内障治疗。

ReSTOR multifocal intraocular lens

ZHUO Jian, CAI Keli   

  1. Department of Ophthalmology, Qilu Hospital of Shandong University, Jinan 250012, China
  • Received:2009-01-20 Published:2009-07-16

摘要:

目的探讨ReSTOR多焦点人工晶体的临床应用效果。方法选取30例(60眼)老年性白内障患者,按统一标准分为两组,其中双眼非同期植入ReSTOR多焦点人工晶体者15例设为MIOL组;双眼非同期植入单焦点人工晶体者15例设为SIOL组。均行角膜缘透明角膜切口,应用超声乳化术摘除白内障联合人工晶体植入。术后1?d观察术眼的屈光状态,裸眼远、近视力;术后1个月观察术眼的屈光状态,裸眼远、近视力,矫正远、近视力,最佳远矫下近视力,焦距深度,对比敏感度,远近立体视锐度,问卷调查视觉质量、各视觉功能区满意度及脱镜率。结果术中术后无严重并发症。两组患者术后均有良好的远视力;MIOL组患者同时获得良好的近、中程视力。术后对比敏感度MIOL组较SIOL组有所下降,但无功能性意义。MIOL组有80%(12例)的患者裸眼近立体视锐度≤60?s,SIOL组所有患者裸眼近立体视锐度≥400?s,差异有统计学意义(χ2=26.28,P<0.05);MIOL组有93.33%(14例)的患者矫正近视力下近立体视锐度≤60?s,SIOL组有33.33%(5例)患者矫正近视立下近立体视锐度≤60?s,差异有统计学意义(χ2=12.59,P<0.05)。MIOL组视近脱镜率80%。结论ReSTOR多焦点人工晶体植入安全有效,可为患者提供良好的全程视力及双眼视觉,患者满意度较高。

关键词: 多焦点人工晶体;全程视力;双眼视觉;对比敏感度, 牙本质粘结剂;激光;牙本质通透性;牙本质过敏症

Abstract:

To evaluate the clinical effect of the ReSTOR multifocal intraocular lens. Metheods30 agerelated cataract patients (sixty eyes) were divided into two groups with the same standard.All patients accepted phacoemulsification and IOL implantation.15 patients were bilaterally implanted with the Alcon ReSTOR stepprogressivediffraction foldable multifocal IOL(MIOL)and 15 with  Alcon Nature bluefilter foldable monofocal IOL(SIOL). Distance visual acuity, near visual acuity and depth of focus were observed postoperatively at day l and 30. Binocular vision functions including contrast sensitivity (CS)and stereopsis acuity were determined postoperatively at day 30. Also, visual quality and postoperative satisfactory were evaluated by questionaires.  ResultsAll patients had good distance visual acuity postoperatively.The MIOL group was better than the SIOL group in uncorrected near visual acuity. MIOL could provide 4.50?D amplitude of functional vision.CS in the MIOL group was lower than in the SIOL group, particularly at 3 cycles per degree, but no one complained about it. In the MIOL group, 80% of the patients had a 60?s or less of near stereopsis acuity with an uncorrected near visual acuity.In the SIOL group, no one had the same level(χ2=26.28,P<0.05). In the MIOL group, 93.33% of the patients had a 60?s or less of near stereopsis acuity with corrected near visual acuity, while in the SIOL group, 33.33% of them had the  same level(χ2=12.59,P<0.05). Between the two groups,there were no statistical differences in distance stereopsis acuity. In the MIOL group, 80% of the patients achieved total spectacle independence. ConclusionThe ReSTOR multifocal IOL provides a satisfactory full range of vision and binocular vision function.

Key words: Multifocal intraocular lens; Full range of vision; Binocular vision function; Contrast sensitivity, Dentinbonding agents; Laser; Dentin tubule permeability; Dentin hypersensitivity