JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES)

• Articles • Previous Articles     Next Articles

Broken custommade tumor prosthesis with a finite element method and sleeve prosthesis for revision

LIU Wen-guang1,LI Jian-min1,LIU Kai-hong2,YANG Zhi-ping1,LI Xin1   

  1. 1. Department of Orthopedics, Qilu Hospital of Shandong University, Jinan 250012, China; 2. School of Materials Science and Engineering, Shandong University, Jinan 250061, China
  • Received:2007-11-03 Revised:1900-01-01 Online:2008-04-16 Published:2008-04-16
  • Contact: LI Jian-min

Abstract: To analyze the biomechanics characteristics of broken tumor prosthesis and optimize it with a finite element method and to evaluate the sleeve prosthesis in revision for custommade tumor prosthesis fracture. MethodsThe CT data of femur treated by software Mimics were imported into software UG2.0 to make models, and the prosthesis models were made based on the prosthesis dimension. Then the femur and prosthesis were assembled as the operations did and imported into a threedimensional finite element software ABAQUS6.5 to make a mechanics loading analysis. The sleeve revision prosthesis was designed to repair fracture of the extramedullary site of custommade tumor prosthesis with no losing. ResultsIn the broken prosthesis, conjunction of the femoral neck and the extramedullary site, conjunction of the extramedullary site and intramedullary site, one third of the intramedullary site on the exterior and interior had stress concentration, but stress of the extramedullary part was weak. Followed up for 19 months, no infection, losing, fracture of prosthesis, recurrence and metastasis, inequality of lower limb were observed. The Enneking score of preoperation was 1, of postoperation was 26, and of the last followed-up was 25. ConclusionWe should strengthen many aspects of custommade tumor prosthesis on the stress concentration site such as the diameter, shape and material. Sleeve revision prosthesis has a highly value and a good initial clinical effect in its indication.

Key words: Hip prosthesis, Revision, Sleeve joint prosthesis, 3-D finite element

CLC Number: 

  • R687.4
[1] WANG Chao, ZHANG Wei, GUAN Da-wei, LI Wei, WANG Xian-quan, WANG Wen-hao. Treatment of Vancouver type B3 periprosthetic femoral fracture with greater trochanter reattachment device and cortical strut bone allograft [J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2013, 51(2): 88-92.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!