您的位置:山东大学 -> 科技期刊社 -> 《山东大学学报(医学版)》

山东大学学报(医学版) ›› 2010, Vol. 48 ›› Issue (9): 76-.

• 论文 • 上一篇    下一篇

硬性透气性角膜接触镜矫正圆锥角膜的视觉质量分析

温莹1,2, 吴欣怡1,季鹏2,王桂敏2,李海燕2   

  1. 1.山东大学齐鲁医院眼科, 济南 250012; 2.山东施尔明眼科医院, 济南 250002
  • 收稿日期:2010-06-21 出版日期:2010-09-16 发布日期:2010-09-16
  • 通讯作者: 吴欣怡,女,教授,博士生导师,主要从事角膜病、白内障方面的研究。 E-mail:xywu8868@163.com
  • 作者简介:温莹(1975- ),女,博士研究生,现工作单位为山东施尔明眼科医院,主要从事角膜病、眼底病方面的研究。E-mail:wenyingeye@sina.com

Analysis of visual performance corrected by rigid gas permeable contact lens in keratoconus

WEN Ying1,2, WU Xin-yi1, JI Peng2, WANG Gui-min2, LI Hai-yan2   

  1. 1. Department of Ophthalmology, Qilu Hospital of Shandong University,  Jinan 250012, China;
    2. Shandong Shierming Eye Hospital, Jinan 250002, China
  • Received:2010-06-21 Online:2010-09-16 Published:2010-09-16

摘要:

目的     分析硬性透气性角膜接触镜(RGPCL)矫正圆锥角膜的视觉质量。方法     采用回顾性病例对照研究。18例(36眼)圆锥角膜患者配戴RGPCL后,通过视力、对比敏感度检查评价视功能;通过角膜地形图、波前像差检查分析影响视觉质量的原因。将同期配戴RGPCL、最佳矫正视力达1.0的近视患者9例(18眼)作为对照组。结果     所有圆锥角膜患者配戴RGPCL后最佳矫正视力均大于或等于0.6,22眼(61.11%)最佳矫正视力达1.0。与近视组比较,RGPCL矫正圆锥角膜后的对比敏感度在低频段差异无统计学意义(P>0.05),中频段的暗视对比度和高频段的明视、暗视对比度均明显降低(P<0.05)。角膜地形图显示RGPCL使圆锥角膜组角膜散光由(8.25±3.61)D减少至(1.25±0.13)D,近视组角膜散光由(1.28±0.34)D减少至(0.42±0.06)D。经RGPCL矫正后,圆锥角膜组的总高阶像差、慧差、球差的均方根值明显高于近视组(P<0.05)。结论    RGPCL能将圆锥角膜的视力矫正至正常或接近正常,残余散光和高阶像差的存在可能是影响视觉质量的原因。

关键词: 圆锥角膜;接触镜;对比敏感度;视觉质量

Abstract:

Objective     To analyze visual performance in keratoconus with rigid gas permeable contact lens (RGPCL). Methods      18 keratoconic patients (36 eyes) who were fitted with RGPCL were enrolled as keratoconus group. 9 myopic patients(18 eyes) with RGPCL were enrolled as the myopia group. Visual acuity(VA) and contrast sensitivity were examined to evaluate visual performance(VP). Corneal astigmatism and wavefront error were measured to analyze the influencing factors of VP. Results    All keratoconic eyes got corrected VA of 0.6 or better.61.11% of them reached 1.0. There was no difference between the two groups in low frequency of contrast sensitivity(P>0.05).But in the middle frequency of light-off contrast sensitivity and in the high frequency of contrast sensitivity,the keratoconus group was significantly lower than the myopia group(P<0.05). Corneal astigmatism was reduced from (8.25±3.61)D to (1.25±0.13)D in the keratoconus group and from(1.28±0.34)D to (0.42±0.06)D in the myopia group. The root-meansquare of total higher-order aberrations (HOAs), coma-like aberration and spherical-like aberrations in the keratoconus group were significantly higher than those in the myopia group(P<0.05). Conclusion     Through RGPCL, keratoconic eyes can get corrected VA as well as myopic eyes with RGPCL, but can not get ideal visual performance. The degradation of visual performance may be related to residual corneal astigmatism and HOAs in keratoconic eyes with RGPCL.

Key words: Keratoconus; Contact lens; Contrast sensitivity; Visual performance

中图分类号: 

  • R772.2
[1] 陈红梅1,卓建2. 白内障超声乳化吸除术后泪膜的变化及影响因素[J]. 山东大学学报(医学版), 2011, 49(4): 133-.
[2] . RBCD患者角膜上皮细胞的凋亡[J]. 山东大学学报(医学版), 2009, 47(10): 130-133.
[3] 陈国玲 陈双 肖瑛 毛淑芝 高雪 刘执玉. 大黄素对急性角膜炎症反应中ICAM-1表达的影响及意义[J]. 山东大学学报(医学版), 2009, 47(5): 31-33.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   