Journal of Shandong University (Health Sciences) ›› 2026, Vol. 64 ›› Issue (11): 48-55.doi: 10.6040/j.issn.1671-7554.0.2026.0498
• Clinical Medicine • Previous Articles
BIAN Tao*, LI Lei*, WANG Zhaolun, YANG Dejin, ZHOU Yixin
CLC Number:
| [1] Tanzer M, Am M. Preoperative planning in primary total knee arthroplasty[J]. J Am Acad Orthop Surg, 2016, 24(4): 220-230. [2] Matassi F, Pettinari F, Frasconà F, et al. Coronal alignment in total knee arthroplasty: a review[J]. J Orthop Traumatol, 2023, 24(1): 24. DOI: 10.1186/s10195-023-00702-w [3] Begum F A, Kayani B, Magan A A, et al. Current concepts in total knee arthroplasty: mechanical, kinematic, anatomical, and functional alignment[J]. Bone Jt Open, 2021, 2(5): 332-340. [4] Bellemans J, Colyn W, Vandenneucker H, et al. The Chitranjan Ranawat award: is neutral mechanical alignment normal for all patients? The concept of constitutional varus[J]. Clin Orthop Relat Res, 2012, 470(1): 45-53. [5] Yang H Y, Seon J K, Ayob K A. Evolving philosophies of alignment in TKA: from mechanical uniformity to personalised harmony[J]. Medicina(Kaunas), 2026, 62(2): 307. DOI:10.3390/medicina62020307 [6] MacDessi S J, Griffiths-Jones W, Harris I A, et al. Coronal plane alignment of the knee(CPAK)classification[J]. Bone Jt J, 2021, 103-B(2): 329-337. [7] Gieroba T J, Marasco S, Babazadeh S, et al. Arithmetic hip knee angle measurement on long leg radiograph versus computed tomography: inter-observer and intra-observer reliability[J]. Arthroplasty, 2023, 5(1): 35. DOI:10.1186/s42836-023-00193-4 [8] 乔桦, 李慧武. 膝关节置换手术机器人应用现状与研究进展[J].山东大学学报(医学版), 2023, 61(3): 29-36. Qiao Hua, Li Huiwu. Application status and research progress of knee arthroplasty surgical robot[J]. Journal of Shandong University(Health Science), 2023, 61(3): 29-36. [9] Tarassoli P, Corban L E, Wood J A, et al. Long leg radiographs underestimate the degree of constitutional varus limb alignment and joint line obliquity in comparison with computed tomography: a radiographic study[J]. Knee Surg Phys Traumatol Arthrosc, 2023, 31(11): 4755-4765. [10] Itou J, Gazali I, Pandit H, et al. The CPAK classification in three-dimensional measurements is consistent with those in two-dimensional measurements[J]. Arch Orthop Trauma Surg, 2025, 145(1): 160. DOI:10.1007/s00402-024-05742-3 [11] Jhurani A, Lavaniya S, Ardawatia G, et al. Computed tomography versus long-leg radiography for CPAK-based coronal alignment assessment in total knee arthroplasty: a prospective evaluation[J]. J Rob Surg, 2025, 20(1): 120. DOI:10.1007/s11701-025-03072-z [12] Glowalla C, Langer S, Lenze U, et al. Postoperative full leg radiographs exhibit less residual coronal varus deformity compared to intraoperative measurements in robotic arm-assisted total knee arthroplasty with the MakoTM system[J]. Knee Surg Phys Traumatol Arthrosc, 2023, 31(9): 3912-3918. [13] Wong W K, Zulkhairi S Z, Chua H S. CT-based software-generated measurements permit more objective assessments of arithmetic hip-knee-ankle axis and joint line obliquity[J]. Life(Basel), 2025, 15(2): 188. DOI:10.3390/life15020188 [14] Yang H Y, Ayob K A, Jeong H W, et al. Full-length weight-bearing radiographs and computed tomography show discrepancies in coronal alignment for robotic arm-assisted total knee arthroplasty[J]. Sci Rep, 2025, 15(1): 10099. DOI:10.1038/s41598-025-93542-z [15] Fontalis A, Luyckx T, Vanspauwen T, et al. Strong correlation between standing long-leg radiographs and CT scans in measuring coronal knee alignment[J]. J Bone Jt Surg Am, 2024, 106(15): 1373-1383. [16] 刘浩洋, 李宏旭, 周宇, 等. 机器人辅助与传统全膝关节置换临床功能及影像学的差异[J].中国组织工程研究, 2026, 30(15): 3936-3945. Liu Haoyang, Li Hongxu, Zhou Yu, et al. Differences in clinical function and imaging between robot-assisted and conventionaltotal knee arthroplasty[J]. Journal of Clinical Rehabilitative Tissue Engineering Research, 2026, 30(15): 3936-3945. [17] Griffiths-Jones W, Chen D B, Harris I A, et al. Arithmetic hip-knee-ankle angle(aHKA): an algorithm for estimating constitutional lower limb alignment in the arthritic patient population[J]. Bone Jt Open, 2021, 2(5): 351-358. [18] 马成元, 王建朋, 赵光辉, 等. 中国西北地区膝骨关节炎患者冠状面对线的分布特征分析[J].实用骨科杂志, 2025, 31(12): 1083-1088. Ma Chengyuan, Wang Jianpeng, Zhao Guanghui, et al. Analysis of coronal plane alignment distribution characteristics and gender/body mass index differences in patients with knee osteoarthritis in Northwest China[J]. Journal of Practical Orthopaedics, 2025, 31(12): 1083-1088. [19] Bland J M, Altman D G. Statistical methods for assessing agreement between two methods of clinical measurement[J]. Lancet, 1986, 327(8476): 307-310. [20] Zou G. Confidence interval estimation for the Bland-Altman limits of agreement with multiple observations per individual[J]. Stat Meth Med Res, 2013, 22(6): 630-642. [21] Ahrend M D, Baumgartner H, Ihle C, et al. Influence of axial limb rotation on radiographic lower limb alignment: a systematic review[J]. Arch Orthop Trauma Surg, 2022, 142(11): 3349-3366. [22] Hirschmann M T, Konala P, Amsler F, et al. The position and orientation of total knee replacement components: a comparison of conventional radiographs, transverse 2D-CT slices and 3D-CT reconstruction[J]. J Bone Jt Surg Br Volume, 2010, 92(5): 692-699. [23] Sasaki R, Niki Y, Kaneda K, et al. Discrepancies in long-leg alignment and knee joint line obliquity between two- and three-dimensional measurements under weight-bearing conditions: effects on coronal plane alignment of the knee classification[J]. Knee, 2025, 53: 237-245. DOI:10.1016/j.knee.2024.12.008 [24] Chen J Z, Geng X, Wang C, et al. Coronal plane alignment of the knee classification in patients with osteoarthritis and the clinical outcomes of its alteration in total knee arthroplasty: a cross-sectional analysis of a Chinese cohort[J]. Int Orthop, 2025, 49(5): 1081-1090. [25] Sires J D, Craik J D, Wilson C J. Accuracy of bone resection in Mako total knee robotic-assisted surgery[J]. J Knee Surg, 2021, 34(7): 745-748. |
| [1] | JIN Tong, WEI Xingzhou, JIN Chenyang, RAO Zhaobin, XIA Hanrong, ZHU Feng, WANG Yijun, ZHANG Lianfang, CHEN Guangdong, LI Rongqun, XU Yaozeng, ZHOU Jun. Comparison of coronal plane alignment of the knee phenotypes between knee osteoarthritis patients and asymptomatic controls [J]. Journal of Shandong University (Health Sciences), 2026, 64(6): 43-49. |
| [2] | SONG Ke, MU Zongyou, ZHAI Shenhao, NIU Chuang, GUO Yaqi, ZHANG Tengteng, REN Xuebing, LIU Peilai. Analgesic effect of bupivacaine liposome after total knee arthroplasty [J]. Journal of Shandong University (Health Sciences), 2026, 64(2): 111-117. |
| [3] | MA Liang, YAN Shuaichen, LI Deqiang, JIANG Shuwei, YANG Huapu, ZHANG Yuankai. Brucella periprosthetic joint infection following total joint arthroplasty: three cases report and literature review [J]. Journal of Shandong University (Health Sciences), 2024, 62(12): 90-95. |
| [4] | Orthopaedic Rehabilitation Special Committee of Chinese Speaking Orthopaedic Society. Expert consensus on accelerated recovery of knee function after total knee arthroplasty [J]. Journal of Shandong University (Health Sciences), 2024, 62(10): 48-61. |
| [5] | JIANG Rendong, ZHAO Jianli, SHI Chao, HE Yeteng, YUAN Zhen. Clinical outcomes comparison of total knee arthroplasty in patients with rheumatoid arthritis and osteoarthritis under the concept of enhanced recovery after surgery [J]. Journal of Shandong University (Health Sciences), 2024, 62(10): 62-67. |
| [6] | LI Xue, ZHANG Zengzhen, LIU Jisong, LI Deqiang, YANG Shaozhong. Effect of ultrasound-guided genicular nerve block on postoperative pain in patients undergoing total knee arthroplasty [J]. Journal of Shandong University (Health Sciences), 2024, 62(10): 68-75. |
| [7] | GUO Yongyuan, SUN Houyi, ZHANG Yuankai, YAN Tingbin, LIU Peilai, JIA Yuhua. Learning curve of domestic “Skywalker” robotic-assisted total knee arthroplasty [J]. Journal of Shandong University (Health Sciences), 2023, 61(3): 115-120. |
| [8] | ZHAO Heng, YIN Qingfeng, LIU Wenguang, LIU Shenghou, XIAO Shipeng, WANG Shaojin. Application of a novel barbed suture in wound closure of hip and knee replacement [J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2015, 53(8): 53-56. |
| [9] | HUANG Chuanwang, Salim Jeddo, ZHANG Yuankai, LI Deqiang, LIU Peilai, LI Ming. Use of metal block in total knee arthroplasty with tibial bone defect [J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2015, 53(6): 90-93. |
|
||