Journal of Shandong University (Health Sciences) ›› 2026, Vol. 64 ›› Issue (11): 48-55.doi: 10.6040/j.issn.1671-7554.0.2026.0498

• Clinical Medicine • Previous Articles    

Consistency between planned and postoperative measured angles in Mako robot-assisted total knee arthroplasty and its impact on coronal plane alignment of the knee classification

BIAN Tao*, LI Lei*, WANG Zhaolun, YANG Dejin, ZHOU Yixin   

  1. Department of Orthopaedics, Beijing Jishuitan Hospital, Capital Medical University, Beijing 100035, China
  • Published:2026-11-20

Abstract: Objective To investigate the consistency between intraoperative planned angles based on three-dimensional computed tomography(CT)modeling and postoperative measured angles based on two-dimensional long-leg radiographs in Mako robot-assisted total knee arthroplasty(TKA), and to quantitatively evaluate the impact of any discre-pancies on the Coronal Plane Alignment of the Knee(CPAK)classification. Methods A retrospective analysis was conducted on 194 patients(212 knees)who underwent primary Mako robot-assisted TKA between June and December 2024. Intraoperative planned medial proximal tibial angle(MPTA)and lateral distal femoral angle(LDFA)were directly extracted from the robotic system. Postoperative long-leg radiographs were independently measured by two blinded observers to obtain corresponding angles. The arithmetic hip-knee-ankle angle(aHKA)and joint line obliquity(JLO)were calculated, and CPAK classification was performed. Paired t-tests, Bland-Altman analysis, and Cohens Kappa coefficient were used to compare the agreement of angle measurements and classification between the two methods. Results Postoperative radiographic MPTA was significantly larger(more valgus)than the intraoperative CT-planned value, with a mean difference of 0.70°(95%CI: 0.52° to 0.88°, P<0.001), while no significant difference was observed for LDFA(P=0.154), resulting in a more neutral postoperative aHKA compared to the planned value(mean difference: 0.82°, P<0.001). Bland-Altman analysis revealed wide 95% limits of agreement for MPTA(-1.90° to 3.31°). Correlation between measurements from the two methods was moderate across all angular parameters(ICC range: 0.452 to 0.561). The overall agreement rate for CPAK classification was 53.8%, with a Kappa value of 0.310(fair agreement). The predominant reclassification pathway was from intraoperative planned "type IV" to postoperative measured "type V"(38 knees, accounting for 38.8% of all discordant knees). Conclusion In Mako robot-assisted TKA, postoperative radiographic measurements demonstrate a systematic valgus offset compared to intraoperative CT-based planning, primarily manifested in MPTA, leading to altered CPAK classification in nearly half of the patients. Surgeons should be aware of differences between imaging modalities when pursuing CPAK-guided personalized alignment targets.

Key words: Mako robot-assisted surgery, Total knee arthroplasty, Lower limb alignment, Medial proximal tibial angle, Coronal plane alignment of the knee classification

CLC Number: 

  • R574
[1] Tanzer M, Am M. Preoperative planning in primary total knee arthroplasty[J]. J Am Acad Orthop Surg, 2016, 24(4): 220-230.
[2] Matassi F, Pettinari F, Frasconà F, et al. Coronal alignment in total knee arthroplasty: a review[J]. J Orthop Traumatol, 2023, 24(1): 24. DOI: 10.1186/s10195-023-00702-w
[3] Begum F A, Kayani B, Magan A A, et al. Current concepts in total knee arthroplasty: mechanical, kinematic, anatomical, and functional alignment[J]. Bone Jt Open, 2021, 2(5): 332-340.
[4] Bellemans J, Colyn W, Vandenneucker H, et al. The Chitranjan Ranawat award: is neutral mechanical alignment normal for all patients? The concept of constitutional varus[J]. Clin Orthop Relat Res, 2012, 470(1): 45-53.
[5] Yang H Y, Seon J K, Ayob K A. Evolving philosophies of alignment in TKA: from mechanical uniformity to personalised harmony[J]. Medicina(Kaunas), 2026, 62(2): 307. DOI:10.3390/medicina62020307
[6] MacDessi S J, Griffiths-Jones W, Harris I A, et al. Coronal plane alignment of the knee(CPAK)classification[J]. Bone Jt J, 2021, 103-B(2): 329-337.
[7] Gieroba T J, Marasco S, Babazadeh S, et al. Arithmetic hip knee angle measurement on long leg radiograph versus computed tomography: inter-observer and intra-observer reliability[J]. Arthroplasty, 2023, 5(1): 35. DOI:10.1186/s42836-023-00193-4
[8] 乔桦, 李慧武. 膝关节置换手术机器人应用现状与研究进展[J].山东大学学报(医学版), 2023, 61(3): 29-36. Qiao Hua, Li Huiwu. Application status and research progress of knee arthroplasty surgical robot[J]. Journal of Shandong University(Health Science), 2023, 61(3): 29-36.
[9] Tarassoli P, Corban L E, Wood J A, et al. Long leg radiographs underestimate the degree of constitutional varus limb alignment and joint line obliquity in comparison with computed tomography: a radiographic study[J]. Knee Surg Phys Traumatol Arthrosc, 2023, 31(11): 4755-4765.
[10] Itou J, Gazali I, Pandit H, et al. The CPAK classification in three-dimensional measurements is consistent with those in two-dimensional measurements[J]. Arch Orthop Trauma Surg, 2025, 145(1): 160. DOI:10.1007/s00402-024-05742-3
[11] Jhurani A, Lavaniya S, Ardawatia G, et al. Computed tomography versus long-leg radiography for CPAK-based coronal alignment assessment in total knee arthroplasty: a prospective evaluation[J]. J Rob Surg, 2025, 20(1): 120. DOI:10.1007/s11701-025-03072-z
[12] Glowalla C, Langer S, Lenze U, et al. Postoperative full leg radiographs exhibit less residual coronal varus deformity compared to intraoperative measurements in robotic arm-assisted total knee arthroplasty with the MakoTM system[J]. Knee Surg Phys Traumatol Arthrosc, 2023, 31(9): 3912-3918.
[13] Wong W K, Zulkhairi S Z, Chua H S. CT-based software-generated measurements permit more objective assessments of arithmetic hip-knee-ankle axis and joint line obliquity[J]. Life(Basel), 2025, 15(2): 188. DOI:10.3390/life15020188
[14] Yang H Y, Ayob K A, Jeong H W, et al. Full-length weight-bearing radiographs and computed tomography show discrepancies in coronal alignment for robotic arm-assisted total knee arthroplasty[J]. Sci Rep, 2025, 15(1): 10099. DOI:10.1038/s41598-025-93542-z
[15] Fontalis A, Luyckx T, Vanspauwen T, et al. Strong correlation between standing long-leg radiographs and CT scans in measuring coronal knee alignment[J]. J Bone Jt Surg Am, 2024, 106(15): 1373-1383.
[16] 刘浩洋, 李宏旭, 周宇, 等. 机器人辅助与传统全膝关节置换临床功能及影像学的差异[J].中国组织工程研究, 2026, 30(15): 3936-3945. Liu Haoyang, Li Hongxu, Zhou Yu, et al. Differences in clinical function and imaging between robot-assisted and conventionaltotal knee arthroplasty[J]. Journal of Clinical Rehabilitative Tissue Engineering Research, 2026, 30(15): 3936-3945.
[17] Griffiths-Jones W, Chen D B, Harris I A, et al. Arithmetic hip-knee-ankle angle(aHKA): an algorithm for estimating constitutional lower limb alignment in the arthritic patient population[J]. Bone Jt Open, 2021, 2(5): 351-358.
[18] 马成元, 王建朋, 赵光辉, 等. 中国西北地区膝骨关节炎患者冠状面对线的分布特征分析[J].实用骨科杂志, 2025, 31(12): 1083-1088. Ma Chengyuan, Wang Jianpeng, Zhao Guanghui, et al. Analysis of coronal plane alignment distribution characteristics and gender/body mass index differences in patients with knee osteoarthritis in Northwest China[J]. Journal of Practical Orthopaedics, 2025, 31(12): 1083-1088.
[19] Bland J M, Altman D G. Statistical methods for assessing agreement between two methods of clinical measurement[J]. Lancet, 1986, 327(8476): 307-310.
[20] Zou G. Confidence interval estimation for the Bland-Altman limits of agreement with multiple observations per individual[J]. Stat Meth Med Res, 2013, 22(6): 630-642.
[21] Ahrend M D, Baumgartner H, Ihle C, et al. Influence of axial limb rotation on radiographic lower limb alignment: a systematic review[J]. Arch Orthop Trauma Surg, 2022, 142(11): 3349-3366.
[22] Hirschmann M T, Konala P, Amsler F, et al. The position and orientation of total knee replacement components: a comparison of conventional radiographs, transverse 2D-CT slices and 3D-CT reconstruction[J]. J Bone Jt Surg Br Volume, 2010, 92(5): 692-699.
[23] Sasaki R, Niki Y, Kaneda K, et al. Discrepancies in long-leg alignment and knee joint line obliquity between two- and three-dimensional measurements under weight-bearing conditions: effects on coronal plane alignment of the knee classification[J]. Knee, 2025, 53: 237-245. DOI:10.1016/j.knee.2024.12.008
[24] Chen J Z, Geng X, Wang C, et al. Coronal plane alignment of the knee classification in patients with osteoarthritis and the clinical outcomes of its alteration in total knee arthroplasty: a cross-sectional analysis of a Chinese cohort[J]. Int Orthop, 2025, 49(5): 1081-1090.
[25] Sires J D, Craik J D, Wilson C J. Accuracy of bone resection in Mako total knee robotic-assisted surgery[J]. J Knee Surg, 2021, 34(7): 745-748.
[1] JIN Tong, WEI Xingzhou, JIN Chenyang, RAO Zhaobin, XIA Hanrong, ZHU Feng, WANG Yijun, ZHANG Lianfang, CHEN Guangdong, LI Rongqun, XU Yaozeng, ZHOU Jun. Comparison of coronal plane alignment of the knee phenotypes between knee osteoarthritis patients and asymptomatic controls [J]. Journal of Shandong University (Health Sciences), 2026, 64(6): 43-49.
[2] SONG Ke, MU Zongyou, ZHAI Shenhao, NIU Chuang, GUO Yaqi, ZHANG Tengteng, REN Xuebing, LIU Peilai. Analgesic effect of bupivacaine liposome after total knee arthroplasty [J]. Journal of Shandong University (Health Sciences), 2026, 64(2): 111-117.
[3] MA Liang, YAN Shuaichen, LI Deqiang, JIANG Shuwei, YANG Huapu, ZHANG Yuankai. Brucella periprosthetic joint infection following total joint arthroplasty: three cases report and literature review [J]. Journal of Shandong University (Health Sciences), 2024, 62(12): 90-95.
[4] Orthopaedic Rehabilitation Special Committee of Chinese Speaking Orthopaedic Society. Expert consensus on accelerated recovery of knee function after total knee arthroplasty [J]. Journal of Shandong University (Health Sciences), 2024, 62(10): 48-61.
[5] JIANG Rendong, ZHAO Jianli, SHI Chao, HE Yeteng, YUAN Zhen. Clinical outcomes comparison of total knee arthroplasty in patients with rheumatoid arthritis and osteoarthritis under the concept of enhanced recovery after surgery [J]. Journal of Shandong University (Health Sciences), 2024, 62(10): 62-67.
[6] LI Xue, ZHANG Zengzhen, LIU Jisong, LI Deqiang, YANG Shaozhong. Effect of ultrasound-guided genicular nerve block on postoperative pain in patients undergoing total knee arthroplasty [J]. Journal of Shandong University (Health Sciences), 2024, 62(10): 68-75.
[7] GUO Yongyuan, SUN Houyi, ZHANG Yuankai, YAN Tingbin, LIU Peilai, JIA Yuhua. Learning curve of domestic “Skywalker” robotic-assisted total knee arthroplasty [J]. Journal of Shandong University (Health Sciences), 2023, 61(3): 115-120.
[8] ZHAO Heng, YIN Qingfeng, LIU Wenguang, LIU Shenghou, XIAO Shipeng, WANG Shaojin. Application of a novel barbed suture in wound closure of hip and knee replacement [J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2015, 53(8): 53-56.
[9] HUANG Chuanwang, Salim Jeddo, ZHANG Yuankai, LI Deqiang, LIU Peilai, LI Ming. Use of metal block in total knee arthroplasty with tibial bone defect [J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2015, 53(6): 90-93.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!