彩色多普勒闪烁伪像相关物理因素的评估分析

王蒙1,王澂1,张迎春1,李杰2, 孙霄2,时丹丹2,商蒙蒙2,宁松2   

  1. 1.苏州大学附属第二医院超声中心, 江苏 苏州 215004;2.山东大学齐鲁医院超声科, 山东 济南 250012
  • 收稿日期:2015-12-31 出版日期:2017-07-10 发布日期:2017-07-10
  • 通讯作者: 李杰. E-mail:jieli301@163.com E-mail:jieli301@163.com
  • 基金资助:
    山东省科技发展计划(2012GSF11847);山东大学齐鲁医院科研基金资助项目、山东大学基本科研业务费专项资金(2015QLMS39)

Evaluation and analysis of the physical factors for the twinkling artifact: a preliminary study

WANG Meng1, WANG Cheng1, ZHANG Yingchun1, LI Jie2, SUN Xiao2, SHI Dandan2, SHANG Mengmeng2, NING Song2   

  1. 1. Ultrasonic Imaging Center, the Second Affiliated Hospital of Soochow Univesity, Suzhou 215004, Jiangsu, China;
    2. Department of Ultrasound, Qilu Hospital of Shandong University, Jinan 250012, Shandong, China
  • Received:2015-12-31 Online:2017-07-10 Published:2017-07-10

摘要: 目的 评估超声波声学特性、结石表面形貌及机器设置条件在闪烁伪像形成中的价值。 方法 应用砂纸及泌尿系结石分别构建体外实验模型,砂纸模型中通过调节IU22声学功率参数(包括机械指数及声波入射角度)改变超声波特性,结石模型分别按照表面粗糙度差异进行结石分组(包括粗糙组,中度粗糙组与光滑组),然后选取两种不同机器设置条件(默认设置与优化设置)进行闪烁伪像成像,应用配对t检验分析比较砂纸模型中垂直辐射组与斜方辐射组闪烁伪像差异;应用重复测量设计的方差分析比较结石模型中不同机器设置条件下不同表面粗糙度结石组间闪烁伪像强度差异;通过线性回归分析分别对砂纸模型中机械指数、结石模型中不同结石粗糙度与闪烁伪像强度之间进行相关性分析。 结果 在砂纸模型中,机械指数与闪烁伪像强度存在显著正相关(r=0.938, P<0.001),斜方辐射组闪烁伪像强度较垂直辐射组明显减弱(P<0.05);泌尿系结石模型中,不同表面粗糙度泌尿系结石的闪烁伪像强度组间差异有统计学意义且其两个影响因素(表面粗糙度与机器设置条件)存在交互作用(P<0.001),相同表面粗糙度的泌尿系结石中的闪烁伪像强度在机器优化设置条件下均明显强于默认设置条件(P<0.001),而在相同机器设置条件下不同组间结石闪烁伪像强度与其表面粗糙程度呈明显正相关(r默认设置条件=0.80, r优化设置条件=0.83, P<0.001)。 结论 砂纸模型及泌尿系结石模型均显示闪烁伪像形成受超声波声学特性、结石表面粗糙度及机器设置条件的共同影响,了解各种相关因素的作用可提升其临床应用价值。

关键词: 闪烁伪像, 评估, 物理因素, 模型

Abstract: Objective To evaluate the value of ultrasonic characteristics, the roughness of the urinary stones and machine settings in the formation of the twinkling artifact. Methods Constructing the experimental model by the sandpaper and the urinary stones respectively. In the sandpaper model part, ultrasonic output characteristics were changed by regulating the mechanical index in the IU 22 machine and the ultrasonic angle; the intensity of the twinkling artifact were compared and evaluated seperately by the correlation analysis and paired t test respectively. In the urinary stone model part, the stones were divided into the rough group, the mid-rough group and the smooth group according to the difference of the surface roughness. The display of the twinkling artifact in different groups were compared under the diverse conditions including the default and optimized settings by repeated measures ANOVA, and the correlation analysis was performed between the twinkling artifact intensity and the roughness. Results In the sandpaper model part, the intensity of the color Doppler twinkling artifact was in obvious proportion with the mechanical index(r=0.938, P<0.001). And when the Doppler angle of the color box was tilted, the number of the color pixels in the scanning 山 东 大 学 学 报 (医 学 版)55卷7期 -王蒙,等.彩色多普勒闪烁伪像相关物理因素的评估分析 \=-condition decreased significantly(P<0.05). In the urinary stone model part, there existed significant difference among different groups and obvious interaction between the urinary stone roughness and the machine settings on the twinkling artifact intensity(P<0.001). The twinkling artifact intensity was improved under the optimized machine settings compared with that of the default conditions in the urinary stones with the same roughness. However, under the same machine settings, a direct proportion relationship was found between the twinkling artifact intensity and the urinary stone roughness with the coefficient being 0.80 and 0.83 respectively(P<0.001). Conclusion Both the sandpaper phantom and urinary stone phantom showed that the formation of the twinkling artifact are affected by the ultrasonic charateristic index, the surface roughness of the urinary stones and the machine settings. Grasping the related factors on the intensity of the twinkling artifact was useful for its clinical applications.

Key words: Twinkling artifact, Model, Physical factors, Evaluation

中图分类号: 

  • R574
[1] Rahmouni A, Bargoin R, Herment A, et al. Color Doppler twinkling artifact in hyperechoic regions[J]. Radiology, 1996, 199(1): 269-271.
[2] Kielar AZ, Shabana W, Vakili M, et al. Prospective evaluation of Doppler sonography to detect the twinkling artifact versus unenhanced computed tomography for identifying urinary tract calculi[J]. J Ultrasound Med, 2012, 31(10): 1619-1625.
[3] Sharma G, Sharma A. Clinical implications and applications of the twinkling sign in ureteral calculus: a preliminary study[J]. J Urol, 2012, 189(6): 2132-2135.
[4] Abdel-Gawad M, Kadasne R, Elsobky E. Correlation between twinkling artifact of color doppler ultrasound and helical CT in diagnosis of ureteral stones[J]. J Urol, 2014, 191(4): e52.
[5] Sen V, Imamoglu C, Kucukturkmen I, et al. Can Doppler ultrasonography twinkling artifact be used as an alternative imaging modality to non-contrast-enhanced computed tomography in patients with ureteral stones? A prospective clinical study[J]. Urolithiasis, 2016[Epub ahead of print] , doi: 10.1007/s00240-016-0891-8.
[6] Masch WR, Cohan RH, Ellis JH, et al. Clinical Effectiveness of prospectively reported sonographic twinkling artifact for the diagnosis of renal calculus in patients without known urolithiasis[J]. Am J Roentgenol, 2016, 206(2): 326-331.
[7] Hammad AY, Miura JT, Turaga KK, et al. A literature review of radiological findings to guide the diagnosis of gallbladder adenomyomatosis[J]. HPB, 2016, 189(2): 129-135.
[8] Joo I, Lee JY, Kim JH, et al. Differentiation of adenomyomatosis of the gallbladder from early-stage, wall-thickening-type gallbladder cancer using high-resolution ultrasound[J]. Euro Radio, 2013, 23(3): 730-738.
[9] Reuben CM, Jeun B, Juluru K. Sonographic twinkling artifact in a renal graft with prolene mesh[J]. J Ultrasound Med, 2010, 29(6): 1011-1013.
[10] Girish G, Caoili EM, Pandya A, et al. Usefulness of the twinkling artifact in identifying implanted mesh after inguinal hernia repair[J]. J Ultrasound Med, 2011, 30(8): 1059-1065.
[11] Wang M, Li J, Xiao J, et al. Systematic analysis of factors related to display of the twinkling artifact by a phantom: an optimized investigation[J]. J Ultrasound Med, 2011, 30(11): 1449-1457.
[12] Kamaya A, Abate S, Nan B, et al. Characterization of a linear streak artifact with pulse inversion tissue harmonics in musculoskeletal sonography[J]. J Ultrasound Med, 2004, 23(12): 1597-1605.
[13] Aytac SK, Ozcan H. Effect of color Doppler system on the twinkling sign associated with urinary tract calculi[J]. J Clin Ultrasound, 1999, 27(8): 433-439.
[14] Zelesco M. The impact of scanning factors on the twinkle artifact in colour Doppler[J]. J Med Imag Radiat Oncol, 2009, 53: A5.
[15] Gao J, Hentel K, Rubin JM. Correlation between twinkling artifact and color doppler carrier frequency: preliminary observations in renal calculi[J]. Ultrasound Med Biol, 2012, 38(9): 1534-1539
[16] Cunitz B, Dunmire B, Paun M. Improved detection of kidney stones using an optimized doppler imaging sequence[J]. IEEE Int Ultrason Symp, 2014, 2014: 452-455
[17] Dillman JR, Kappil M, Weadock WJ, et al. Sonographic twinkling artifact for renal calculus detection: correlation with CT[J]. Radiology, 2011, 259(3): 911-916.
[18] Yanik B, Conkbayir I, Cakmakci E, et al. Color Doppler twinkling artifact in a calcified liver mass[J]. J Clin Ultrasound, 2005, 33(9): 474-476.
[19] Zhao BW, Yang Y, Pan M, et al. Color Doppler twinkling artifact in fetuses with echogenic intracardiac foci: echocardiographic observation and clinical significance[J]. Ultrasound Obstet Gynecol, 2010, 35(5): 548-551.
[20] Tsujimoto F. Microcalcifications in the breast detected by a color Doppler method using twinkling artifacts: some important discussions based on clinical cases and experiments with a new ultrasound modality called multidetector-ultrasonography(MD-US)[J]. J Med Ultrason, 2014, 41(1): 99-108.
[21] OFlynn EA,Sidhu PS. The sonographic twinkling artifact in testicular calcification[J]. J Ultrasound Med, 2009, 28(4): 515-517.
[22] Serter S, Orguc S, Gumus B, et al. Doppler sonographic findings in testicular microlithiasis[J]. International Braz J Urol, 2008, 34(4): 477-482.
[23] Chelfouh N, Grenier N, Higueret D, et al. Characterization of urinary calculi: in vitro study of “twinkling artifact” revealed by color-flow sonography[J]. Am J Roentgenol, 1998, 171(4): 1055-1060.
[24] 刘青,李杰,孙霄,等.彩色多普勒闪烁伪像对泌尿系含钙结石诊断价值的实验研究[J].中华超声影像学杂志,2015, 24(1): 70-73. LIU Qing, LI Jie, SUN Xiao, et al. Diagnostic value of color Doppler twinkling artifact and in urinary calcium stones:an in vitro experiment[J]. Chin J Ultrasonogr, 2015, 24(1): 70-73.
[25] 孙霄,李杰,商蒙蒙,等.应用彩色多普勒闪烁伪像和CT分析尿酸结石和胱氨酸结石成分的实验研究[J].中华超声影像学杂志, 2015, 24(2): 164-167. SUN Xiao, LI Jie, SHANG Mengmeng, et al. Value of color Doppler twinkling artifact and CT in distinguishing uric acid stones from cystine stones:an experimental study[J]. 2015, 24(2): 164-167.
[26] Kim HJ, Lee JY, Jang JY, et al. Color Doppler twinkling artifacts from gallstones: in vitro analysis regarding their compositions and architectures[J]. Ultrasound Med Biol, 2010, 36(12): 2117-2122.
[27] Tsao TF, Tyan YS, Kang RJ, et al. Correlation study of the strength of the color Doppler twinkling artifact with the roughness of the reflecting surface and the Doppler angles[J]. J Med Ultrasound, 2004, 12(4): 119-124.
[1] 赵立星 宋代辉 魏魁杰 殷恺. 颞下颌关节骨关节病动物模型的建立[J]. 山东大学学报(医学版), 2209, 47(6): 25-27.
[2] 陈雨梦,张越,张武林,杨国兴,许衍辉,韩爱军,刘彩娟,郭雨语,陈志敏. 应用大语言模型回答先天性晶状体脱位患儿家长提问的效果[J]. 山东大学学报 (医学版), 2026, 64(5): 88-95.
[3] 马祎涵,袁昕赟,李嘉妮,韩旭,刁启迪,王艳,褚旭,张琨,胡蕾. 成人抑郁障碍患者童年虐待与频繁噩梦的关系:躯体症状的中介效应与社会支持的调节作用[J]. 山东大学学报 (医学版), 2026, 64(5): 96-105.
[4] 乔颖异,岳芳,石兴龙,徐欣颖,吕婧,程传龙,左慧,许青,李秀君. 气象因素和PM2.5及其交互作用对山东省流行性腮腺炎的影响[J]. 山东大学学报 (医学版), 2026, 64(5): 106-115.
[5] 况利,徐何雁. 从精准评估到整合干预:儿童青少年心理健康问题诊疗范式的革新与展望[J]. 山东大学学报 (医学版), 2026, 64(3): 10-16.
[6] 沈君,周爽,杜苗,蒋颖. 青少年情绪障碍患者及其照顾者病耻感与家庭复原力的关系:基于主客体互倚模型[J]. 山东大学学报 (医学版), 2026, 64(3): 65-77.
[7] 王建民,李晓峰,由志涛,董圣杰,赵宇驰,李占菊,邹德鑫,张剑锋,孙涛,杜伟. 基于可解释机器学习的后路腰椎椎体间融合术后慢性疼痛风险预测模型构建[J]. 山东大学学报 (医学版), 2026, 64(2): 78-88.
[8] 魏书生,吴海波,李松林,温镇璘,杨昌骜,卢群山,刘培来. 大型语言模型在骨科手术术前管理中的决策性能及辅助价值[J]. 山东大学学报 (医学版), 2026, 64(2): 104-110.
[9] 徐欣颖,颜伟,石兴龙,岳芳,吕婧,乔颖异,张宇琦,程传龙,左慧,李秀君. 山东省滨州市手足口病的流行特征及影响因素[J]. 山东大学学报 (医学版), 2026, 64(1): 118-125.
[10] 孙爽爽,仉率杰,张伯韬,袁莹,于媛媛,薛付忠. 基于真实世界研究的18~50岁人群急性缺血性卒中影响因素[J]. 山东大学学报 (医学版), 2025, 63(9): 40-46.
[11] 岳芳,乔颖异,石兴龙,徐欣颖,吕婧,程传龙,左慧,崔峰,李秀君. 暖季夜间高温对淄博市居民心血管疾病死亡的影响[J]. 山东大学学报 (医学版), 2025, 63(9): 116-124.
[12] 刘位龙,王玎,赵超,王宁,张旭,苏萍,宋书典,张娜,迟蔚蔚. 基于BERT和图注意力网络的医疗文本因果关系抽取算法[J]. 山东大学学报 (医学版), 2025, 63(8): 61-68.
[13] 申路佳,逯天威,巩伟明,赵岩松,王淑康,袁中尚. 代谢风险评分在2型糖尿病人群心血管结局预测中的应用[J]. 山东大学学报 (医学版), 2025, 63(8): 69-78.
[14] 陈莹莹,王鲁,胡锡峰,朱高培,薛付忠. 基于贝叶斯网络的2型糖尿病患者并发脑卒中风险预测[J]. 山东大学学报 (医学版), 2025, 63(8): 94-102.
[15] 王莹,李怀臣,龙飞,刘铱. 基于三种统计模型的长期空气污染物混合暴露与耐药性结核病发病风险关联[J]. 山东大学学报 (医学版), 2025, 63(7): 92-101.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!