您的位置:山东大学 -> 科技期刊社 -> 《山东大学学报(医学版)》

山东大学学报 (医学版) ›› 2022, Vol. 60 ›› Issue (7): 129-132.doi: 10.6040/j.issn.1671-7554.0.2021.1421

• 临床医学 • 上一篇    

角巩膜铁屑样异物1例

任大壮,周玮琰,赵博军   

  1. 山东大学附属山东省立医院眼科, 山东 济南 250021
  • 发布日期:2022-07-27
  • 通讯作者: 赵博军. E-mail:15168860708@163.com

A case report of corneoscleral iron filing-like foreign body

REN Dazhuang, ZHOU Weiyan, ZHAO Bojun   

  1. Department of Ophthalmology, Shandong Provincial Hospital, Cheeloo College of Medicine, Shandong University, Jinan 250021, Shandong, China
  • Published:2022-07-27

摘要: 目的 对1例隐匿性角巩膜铁屑样异物患者的临床表现、影像学特征、手术方法进行分析,以提高临床医生对于该病的诊疗能力。 方法 回顾我院收治的1例诊断为角巩膜异物患者的临床资料并进行分析,结合相关文献对该疾病进行总结。 结果 患者为31岁男性,左眼被铁屑崩伤1个月余,伤后曾于外院行异物取出治疗,仍有异物感,眼科查体见前房角脓栓,但未见明显异物,经眼眶CT、超声生物显微镜(UBM)检查后确诊为角巩膜异物,随后手术治疗取出异物。 结论 角巩膜异物是常见的眼外伤之一,但是对于病程较长的角巩膜异物,眼科查体往往难以发现,接诊此类患者时,应尽可能详细地采集病史、完善辅助检查,可减少该病的漏诊率。

关键词: 角巩膜异物, 眼外伤, 超声生物显微镜

Abstract: Objective To investigate the clinical manifestations, imaging features and surgical method of a patient diagnosed with corneoscleral foreign body, in order to improve the diagnosis and treatment of this disease. Methods The clinical data of the patient were retrospectively analyzed, and relevant literature was reviewed. Results The patient was a 31-year-old male whose left eye was injured by the crashing of iron filing one month ago. After the injury, the foreign body was removed in a local hospital, but he still had a sensation of foreign body. Ophthalmological examination showed pus plug in the anterior chamber angle, but no obvious foreign body was detected. After orbital CT and ultrasound biomicroscopy(UBM)examination, corneoscleral foreign body was diagnosed and the foreign body was removed with surgery. Conclusion Corneoscleral foreign body is one of the common ophthalmic diseases, but it is hard to diagnose if the duration is long. For such patients, medical history should be collected timely and imaging examinations should be conducted to reduce the rate of misdiagnosis.

Key words: Corneoscleral foreign body, Ocular trauma, Ultrasound biomicroscopy

中图分类号: 

  • R779.12
[1] Kuhn F, Morris R, Witherspoon CD, et al. A standardized classification of ocular trauma[J]. Ophthalmology, 1996, 103(2): 240-243.
[2] Yang CS, Hsieh MH, Hou TY. Predictive factors of visual outcome in posterior segment intraocular foreign body [J]. J Chin Med Assoc, 2019, 82(3): 239-244.
[3] Anguita R, Moya R, Saez V, et al. Clinical presentations and surgical outcomes of intraocular foreign body presenting to an ocular trauma unit [J]. Graefes Arch Clin Exp Ophthalmol, 2021, 259(1): 263-268.
[4] Casini G, Sartini F, Loiudice P, et al. Ocular siderosis: a misdiagnosed cause of visual loss due to ferrous intraocular foreign bodies-epidemiology, pathogenesis, clinical signs, imaging and available treatment options [J]. Doc Ophthalmol, 2021, 142(2): 133-152.
[5] Chao HM, Chen YH, Liu JH, et al. Iron-generated hydroxyl radicals kill retinal cells in vivo: effect of ferulic acid [J]. Hum Exp Toxicol, 2008, 27(4): 327-339.
[6] Tripathy K, Chawla R, Temkar S, et al. Phthisis bulbi-a clinicopathological perspective [J]. Semin Ophthalmol, 2018, 33(6): 788-803.
[7] Siu AW, Cheung JP, To CH, et al. N-acetyl-serotonin reduces copper(I)ion-induced lipid peroxidation in bovine retinal homogenates [J]. Acta Ophthalmol Scand, 2001, 79(1): 69-71.
[8] Politis M, Rosin B, Amer R. Ocular siderosis subsequent to a missed pars plana metallic foreign body that masqueraded as refractory intermediate uveitis [J]. Ocul Immunol Inflamm. 2018, 26(4): 598-600.
[9] Chowdhary S, Garg P, Sawhney V, et al. Unusual missed diagnosis of foreign body: a case report [J]. Int Med Case Rep J, 2020, 13: 187-190.
[10] Modjtahedi BS, Rong A, Bobinski M, et al. Imaging characteristics of intraocular foreign bodies: a comparative study of plain film X-ray, computed tomography, ultrasound, and magnetic resonance imaging [J]. Retina, 2015, 35(1): 95-104.
[11] Martin R. Cornea and anterior eye assessment with slit lamp biomicroscopy, specular microscopy, confocal microscopy, and ultrasound biomicroscopy [J]. Indian J Ophthalmol, 2018, 66(2): 195-201.
[12] Silverman RH. High-resolution ultrasound imaging of the eye-a review [J]. Clin Exp Ophthalmol, 2009, 37(1): 54-67.
[13] Moura MF, Hayashi I, Rocha DM, et al. Evaluation of anterior segment foreign bodies with ultrasound biomicroscopy [J]. Arq Bras Oftalmol, 2012, 75(2): 122-125.
[14] Rong AJ, Fan KC, Golshani B, et al. Multimodal imaging features of intraocular foreign bodies [J]. Semin Ophthalmol, 2019, 34(7,8): 518-532.
[15] Deramo VA, Shah GK, Baumal CR, et al. Ultrasound biomicroscopy as a tool for detecting and localizing occult foreign bodies after ocular trauma [J]. Ophthalmology, 1999, 106(2): 301-305.
No related articles found!