JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES) ›› 2009, Vol. 47 ›› Issue (11): 68-73.

• Articles • Previous Articles     Next Articles

WANG Qian, ZHAN Fengxia, ZHENG Guixi, WANG Chuanxin, HU Zhimin, WANG Hongchun   

  1. 1. Department of Clinical Laboratory Medicine, Qilu Hospital of Shandong University, Jinan 250012, China;
    2. Department of Clinical Laboratory Medicine, School Hospital of Shandong University, Jinan 250100, China
  • Received:2009-05-21 Published:2009-11-16

Abstract:

To analyze the reliability and comparability of different hematology analyzers and to standardize the operation of a contrast test. Methods The carryover rate, precision, total precision and percentage of differences of hematological analyzers were evaluated and differences of items in whole blood were compared by detecting 20 anticoagulant fresh blood samples based on the documents of ICSH and NCCLS. Every 3 blood samples of highvalue, middlevalue and lowvalue were detected by hematological analyzers everyday for 7 days. The relative deviation was calculated by linear regression equation to assess the test inaccuracy of items on every machine. ResultsThe carryover rate of all contrast hematological analyzers were normal except for the white blood cell classification. Coefficient of the variation of the detective items and the total coefficient of variation of different hematological analyzers were all less than 5%. The test results of 20 blood samples detected on different hematological analyzers were analyzed by a q test which indicated that there were no statistical differences between blocks(P>0.05). The correlative coefficient was over 0.97 and the relative deviation was within the range of allowable error. In white blood cell classification, items of neutrophilic granulocytes and lymphocytes had a better correlatability among contrast analyzers and  between by machines and by

CLC Number: 

  • R446.1
[1] CHI Yuan-yuan1, ZHAI Shen-yong2, WEN Hong-ling1, CUI Feng2, SONG Yan-yan1,WANG Ling2,DU Jun2, CAO Hai-xia2, WANG Qian3, ZHANG Shou-feng3, Y . SFTSV RNA detection in sera of patients suffering from fever with
thrombocytopenia syndrome
[J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2012, 50(11): 118-121.
[2] ZHENG Gui-xi, WANG Chuan-xin, LIU Yan-hong, LIANG Yong-yuan. Methodological evaluation of chemiluminescence microparticle
immunoassay for determining HE4
[J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2012, 50(10): 73-76.