Journal of Shandong University (Health Sciences) ›› 2026, Vol. 64 ›› Issue (8): 107-113.doi: 10.6040/j.issn.1671-7554.0.2025.0916

• Clinical Medicine • Previous Articles    

Validation and application of autoverification rules for blood analysis

LYU Jinfeng, ZHAO Hui, QIN Xiangrong, GONG Yanwen, MAO Haiting, MENG Jing   

  1. Department of Clinical Laboratory, The Second Qilu Hospital of Shandong University, Jinan 250033, Shandong, China
  • Published:2026-08-14

Abstract: Objective To establish and validate the rules of autoverification of blood analysis in emergency tests to shorten the median turnaround time(TAT)and standardize report review, and improve the quality of emergency laboratory services. Methods With reference to CLSI AUTO 15-ED1 and WS/T 616-2018 methods for autoverification of quantitative test results in clinical laboratories, the autoverification rules for blood analysis were established based on the working characteristics and instrument specifications of our laboratory. A total of 50,007 emergency clinical specimens from October 1 to December 31, 2021 were collected to verify the coverage and accuracy. Among them, microscope examinations were performed on 500 randomly selected specimens for the performance evaluation of false negative, with a requirement of false negative<5%. All 15,320 clinical specimens from January 1 to January 31, 2022 were evaluated for the effects of using autoverification rules, to analysis the autoverification pass rate, the positive rate of rules and the changes in median TAT. Results The laboratorys autoverification rules for blood analysis involved 35 items in 8 categories, including internal quality control rules, specimen quality rules, critical value rules, parameter range and alarm information rules, delta check rules, consistency rules, logical relationship rules, and special patients. Validation results demonstrated that the rules achieved 100% coverage and 100% accuracy, accompanied by a false negative rate of 2.2%, satisfying the performance criteria. After the application of autoverification rules, the median TAT was shortened by 12.6%, and the autoverification rate of 15,320 specimens was 63.56%. Conclusion The establishment and validation of autoverification rules for blood analysis need to be carried out in an orderly manner under the guidance of documents. The autoverifications can be used after the rules are verified which are personalized and standardized according to the characteristics of the instrument's parameters.

Key words: Autoverification, Blood analysis, Performance verification, Quality control, Emergency laboratory testing

CLC Number: 

  • R446.1
[1] 中华人民共和国国家卫生健康委. 国家卫生健康委员会. 临床实验室定量检验结果的自动审核:WS/T 616-2018[S]. 北京:中国标准出版社,2018.
[2] 胡月明, 李宾, 高光强, 等. 人工智能在检验医学中的应用及展望[J]. 国际检验医学杂志, 2021, 42(6): 753-758.
[3] 张政, 邱骏. 临床实验室检验结果自动审核的应用进展[J]. 临床检验杂志, 2022, 40(10): 725-730.
[4] Rimac V, Lapic I, Kules K, et al. Implementation of the autovalidation algorithm for clinical chemistry testing in the laboratory information system[J]. Lab Med, 2018: 284-291.
[5] 夏良裕, 程歆琦, 刘茜, 等. 临床实验室生化免疫项目自动审核程序的建立与应用[J]. 中华医学杂志, 2017, 97(8): 616-621. Xia Liangyu, Cheng Xinqi, Liu Qian, et al. Developing and application of an autoverification system for clinical chemistry and immunology test results[J]. National Medical Journal of China, 2017, 97(8): 616-621.
[6] Fu Q, Ye C X, Han B, et al. Designing and validating autoverification rules for hematology analysis in sysmex XN-9000 hematology system[J]. Clin Lab, 2020, 66(4/2020): 10-17.
[7] Clinical and Laboratory Standards Institute.Autoverification of medical laboratory results for specific disciplines[S]. 1st ed. CLSI guideline AUTO15. Wayne, PA: Clinical and Laboratory Standards Institute, 2019.
[8] Barnes P W, McFadden S L, Machin S J, et al. The international consensus group for hematology review: suggested criteria for action following automated CBC and WBC differential analysis[J]. Lab Hematol, 2005, 11(2): 83-90.
[9] 魏坚, 王剑飚, 宋卫星, 等. 迈瑞 CAL 8000血液分析流水线自动审核规则的制定与评价[J]. 检验医学, 2015, 30(3): 243-246. Wei Jian, Wang Jianbiao, Song Weixing, et al. Automatic verification procedure and evaluation of Mindray CAL 8000 auto sample processing line[J]. Laboratory Medicine, 2015, 30(3): 243-246.
[10] 续薇, 郝晓柯, 崔巍, 等. 血液分析自动审核规则建立与验证的多中心研究[J]. 中华检验医学杂志, 2018, 41(8): 601-607. Xu Wei, Hao Xiaoke, Cui Wei, et al. A multi-center research on the establishment and validation of autoverification rules for blood analysis[J]. Chinese Journal of Laboratory Medicine, 2018, 41(8): 601-607.
[11] 李映潼, 王学军, 续薇, 等. 血液分析自动审核的周期性验证及其应用适宜性评价[J]. 中华检验医学杂志, 2020, 43(10): 1021-1031. Li Yingtong, Wang Xuejun, Xu Wei, et al. Periodic revalidation of autoverification for blood analysis and its suitability evaluation of application[J]. Chinese Journal of Laboratory Medicine, 2020, 43(10): 1021-1031.
[12] 陆学军, 李传保, 刘梦欣, 等. 血液细胞分析流水线自动审核规则制定与确认[J]. 现代检验医学杂志, 2017, 32(3): 157-161. Lu Xuejun, Li Chuanbao, Liu Mengxin, et al. Study on autoverification systems of hematology analysis system[J]. Journal of Modern Laboratory Medicine, 2017, 32(3): 157-161.
[13] Clinical and Laboratory Standards Institute. Reference Leukocyte(WBC)Differential Count(Proportional)and Evaluation of Instrumental Methods; Approved Standard—Second Edition. CLSIdocument H20-A2 [S]. Wayne, PA: Clinical and Laboratory Standards Institute, 2007.
[14] Clinical and Laboratory Standards Institute. CLSI Document AUTO10-A—Autoverification of clinical laboratory test results; approved guideline[S]. Wayne, PA: Clinical and Laboratory Standards Institute, 2006.
[15] 中国合格评定国家认可委员会. 医学实验室质量和能力认可准则: CNAS-CL02:2023[S]. 北京: 中国合格评定国家认可委员会. 2023:
[16] 中国医学装备协会检验医学分会. 临床实验室检验结果自动审核程序建立及应用专家共识(2025版)[J]. 中华检验医学杂志, 2025, 48(10): 1291-1301.
[17] 温冬梅, 张秀明, 王伟佳, 等. 临床实验室生化免疫自动审核系统的建立及应用[J]. 中华检验医学杂志, 2018, 41(2): 141-148. Wen Dongmei, Zhang Xiuming, Wang Weijia, et al. Establishment and application of the autoverification system in laboratory clinical chemistry and immunology laboratory[J]. Chinese Journal of Laboratory Medicine, 2018, 41(2): 141-148.
[18] 郑善銮, 郝晓柯. 尿液常规分析结果自动审核模块的建立与应用[J]. 中华检验医学杂志, 2011, 34(6): 507-510.
[19] Wang Z Q, Peng C, Kang H, et al. Design and evaluation of a LIS-based autoverification system for coagulation assays in a core clinical laboratory[J]. BMC Med Inform Decis Mak, 2019, 19(1): 123. DOI:10.1186/s12911-019-0848-2
[20] 曲林琳, 吴俊, 吴卫, 等. 凝血检验结果自动审核规则建立与验证的多中心研究[J]. 中华检验医学杂志, 2020, 43(8): 802-811. Qu Linlin, Wu Jun, Wu Wei, et al. A multicenter study on the establishment and validation of autoverification rules for coagulation tests[J]. Chinese Journal of Laboratory Medicine, 2020, 43(8): 802-811.
[21] 郑国娜, 孙晗, 刘晓艳, 等. 迈瑞CAL-8000血液分析流水线自动审核的验证与实施评价[J]. 山东医学高等专科学校学报, 2024, 46(5): 10-12.
[22] Wu J, Pan M C, Ouyang H Z, et al. Establishing and evaluating autoverification rules with intelligent guidelines for arterial blood gas analysis in a clinical laboratory[J]. SLAS Technol, 2018, 23(6): 631-640.
[23] 张慧, 王学军, 樊爱琳, 等. 尿液分析自动审核规则的建立与多中心实践[J]. 中华检验医学杂志, 2020, 43(12): 1217-1224. Zhang Hui, Wang Xuejun, Fan Ailin, et al. A multi-center research on the establishment and validation of autoverification rules for urine analysis[J]. Chinese Journal of Laboratory Medicine, 2020, 43(12): 1217-1224.
[24] Kim H, Hur M, Lee G H, et al. Performance of platelet counting in thrombocytopenic samples: comparison between mindray BC-6800Plus and sysmex XN-9000[J]. Diagnostics, 2021, 12(1): 68. DOI:10.3390/diagnostics12010068
[1] Thoracoscopic Committee of Shandong Provincial Endoscopic Surgery Quality Control Center. Shandong Provincial expert consensus on control indexes of VATS/RATS perioperative quality for non-small cell lung cancer [J]. Journal of Shandong University (Health Sciences), 2025, 63(12): 1-5.
[2] TIAN Hui, LI Shuhai, LI Lin, QI Lei, LU Ming, CHENG Chuanle. Quality control of minimally invasive esophagectomy in Qilu Hospital [J]. Journal of Shandong University (Health Sciences), 2021, 59(9): 78-82.
[3] SHENG Xuan, WANG Yonge, GUO Dan, LAN Meng, FAN Fengjing, DING Hongyu. Effects of body mass index and renal subcutaneous depth on the results of virtual touch tissue imaging quantification in renal transplant patients [J]. Journal of Shandong University (Health Sciences), 2018, 56(12): 68-72.
[4]

GAO Yang, SHAN Ningning, LI Xinhe, LIU Yanhong, XIA Hongyin, WANG Huimin

.

Clinical application of selfmade control serum

[J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2009, 47(04): 72-74.
[5] SONG Li-jie,WANG Wei-hong,LU Jin-ling. Preparation and quality control of penciclovir liposome [J]. JOURNAL OF SHANDONG UNIVERSITY (HEALTH SCIENCES), 2007, 45(6): 635-638.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!