医院PET-CT中心18F正电子放射性药物生产及使用中工作人员的辐射剂量监测

张巍1,2,李士雪1,李连波2,于夕荣2   

  1. 1.山东大学公共卫生学院, 济南 250012; 
    2. 山东省疾病预防控制中心辐射防护安全所, 济南  250014
  • 收稿日期:2012-06-04 出版日期:2012-12-10 发布日期:2012-12-10
  • 通讯作者: 李士雪(1962- ),男,教授,博士生导师,主要从事社会医学与卫生事业管理研究。E-mail: shixueli@sdu.edu.cn
  • 作者简介:张巍(1977-),女,博士研究生,主要从事放射卫生、社会医学与卫生事业管理研究。E-mail:zhangweicdc@163.com

Measurement and evaluation of personal radiation dose in
cyclotron center and PET-CT department

ZHANG Wei1,2, LI Shi-xue1, LI Lian-bo2, YU Xi-rong2   

  1. 1. School of Public Health, Shandong University, Jinan 250012, China;
    2. Institute of Radiological Protection and Safety, Shandong Center for Disease Control and Prevention, Jinan 250014, China
  • Received:2012-06-04 Online:2012-12-10 Published:2012-12-10

摘要:

目的   研究以18F-脱氧葡萄糖(18F-FDG)为代表的正电子放射性药物在生产和使用过程中医务人员的辐射剂量,为临床辐射防护提供参考数据。方法   测量18例工作人员在制药、质控、分装、传送、注射及摆位的工作流程中手、胸部的当量剂量率(d)及操作时间(t),并结合不同年检查工作量(w)估算各工作场所工作人员的年受照剂量。结果   估算得到年检查工作量为1000、4000、7000和10000例时,不同工作环节工作人员的累计年剂量为质控0.27mSv,分装0.02~0.20mSv,传送0.06~0.58mSv,注射2.49~24.9 mSv,摆位1.19~11.91mSv。结论   在现有防护设施和操作条件下, 分装和注射是接受剂量较高的工作环节。当年检查工作量在4000例以上时,从事分装工作的人员手部受照剂量超过国家标准关于职业个人年剂量限值的规定;当年检查工作量在10000例时,从事注射的人员年有效剂量亦超过相关国家标准的规定。

关键词: 正电子药物;18F-脱氧葡萄糖(18F-FDG);PET;辐射剂量;辐射防护

Abstract:

Objective   To measure and evaluate the personal radiation dose for medical staff in cyclotron center and PET-CT department and to offer the reference data for clinical radiation protection. Methods   γ ray radiation dose rate was analyzed in 18 medical staff members during each medical procedure by using X and γ radiation detector. The estimation of annual exposure dose of 18 medical staff at different working site was based on the caculation of doserate(d), work time(t) and workload(w). Results   When the workloads were 1000, 4000, 7000 and 10000 per year, the annual doses per procedure were: 0.27 mSv for quality control; 0.02 to 0.20 mSv for dispensation; 0.06 to 0.58 mSv for carrying the compound; 2.49 to 24.9 mSv for injection and 1.19 to 11.91 mSv for setting the patients. Conclusion   The staff receives higher radiation dose during dispensation and injection. When the workload is 4000 and 10000 per year, the dose received by hands and body would respectively exceed the national radiation safety standards (GBSS) on occupational annual dose limits.

Key words: Positron drug; Deoxyglucose(18F-FDG); PET; Radiation dosage; Radiation protection